Industrial facilities such as oil refineries, chemical plants, gas processing units, pharmaceutical manufacturing facilities and fuel storage terminals often operate in environments where flammable gases, vapours or combustible materials may be present.
In these environments, selecting standard electrical equipment can create serious safety risks. Electrical sparks, excessive surface temperatures or internal faults can potentially become ignition sources.
This is why hazardous area classification plays an important role in industrial equipment selection. Motors, switches, instruments, control systems and electric actuators must be suitable for the specific hazardous conditions in which they are installed.
Understanding Zone 1, Zone 2, Ex d protection, ATEX and IECEx helps engineers identify the right equipment for safe and reliable operation.
What Is Hazardous Area Classification?
Hazardous area classification is the process of identifying and categorising locations where flammable gases, vapours, combustible dusts or other hazardous substances may create an explosive atmosphere.
The classification depends on factors such as:
The type of flammable substance present
The likelihood of an explosive atmosphere forming
The frequency and duration of its presence
The operating conditions of the facility
The ventilation available in the area
The purpose of hazardous area classification is to determine the appropriate equipment protection requirements for electrical and mechanical installations.
Equipment installed in these locations must be selected according to the applicable area classification, gas group, temperature class, equipment protection concept and certification requirements.
Understanding Zone 0, Zone 1 and Zone 2
For locations where explosive gas atmospheres may occur, hazardous areas are commonly classified into Zone 0, Zone 1 and Zone 2.
Zone 0
Zone 0 is an area where an explosive gas atmosphere is present continuously, for long periods, or frequently.
These areas typically require equipment with protection levels appropriate for the highest level of hazardous exposure.
Zone 1
Zone 1 is an area where an explosive gas atmosphere is likely to occur during normal operation.
Examples may include locations near process equipment, gas handling systems, chemical transfer points or areas where flammable vapours may be released during regular operations.
Electrical equipment installed in Zone 1 must be designed and certified for the applicable hazardous conditions.
Zone 2
Zone 2 is an area where an explosive gas atmosphere is not likely to occur during normal operation. If it occurs, it is expected to remain only for a short period.
Equipment selection must still meet the protection requirements of the classified area. Zone 2 does not mean that the location is risk-free.
Zone Classification Comparison
Zone | Presence of explosive gas atmosphere |
|---|---|
Zone 0 | Present continuously, frequently or for long periods |
Zone 1 | Likely to occur during normal operation |
Zone 2 | Unlikely during normal operation, and if present, only for a short duration |
Correct zone classification is essential before specifying an electric actuator, motor, instrument or control device for a hazardous location.
What Does Ex d Mean?
Ex d refers to the flameproof enclosure protection concept used in electrical equipment for explosive atmospheres.
A flameproof enclosure is designed to withstand an internal explosion and prevent the resulting flames or hot gases from igniting the surrounding explosive atmosphere.
The enclosure does not necessarily prevent gases from entering. Instead, its construction, joints and flamepaths are designed to control the consequences of an internal ignition.
This protection concept is particularly relevant to electric actuators containing electrical components and switching mechanisms that could potentially become ignition sources.
Key Characteristics of Ex d Protection
Robust enclosure construction
Designed to contain internal explosions
Controlled flamepaths and enclosure joints
Protection against flame propagation to the surrounding atmosphere
Compliance with applicable explosion-protection standards
Suitability for the specified hazardous-area classification when properly certified
The exact protection level, gas group and temperature class must be verified from the equipment certification and nameplate.
What Is ATEX Certification?
ATEX refers to European requirements governing equipment and protective systems intended for use in potentially explosive atmospheres.
ATEX equipment certification and marking help identify whether equipment is suitable for specific explosive environments.
When selecting a flameproof electric actuator, engineers should check the applicable ATEX marking and certification details, including:
Equipment category
Gas or dust environment
Explosion-protection concept
Gas group
Temperature classification
Equipment protection level
Applicable operating conditions
ATEX compliance should be verified against the actual application and installation requirements rather than assumed from the product description.
What Is IECEx Certification?
IECEx is an international certification system for equipment used in explosive atmospheres.
It is based on international IEC standards and provides a system for evaluating and certifying equipment intended for hazardous locations.
IECEx certification helps users, manufacturers, project engineers and procurement teams verify that equipment has been assessed according to relevant explosion-protection requirements.
When choosing an electric actuator for a hazardous area, IECEx-related documentation may include:
Certificate details
Applicable IEC standards
Explosion-protection marking
Gas group
Temperature class
Equipment protection level
Permitted ambient temperature range
ATEX and IECEx are related to explosion-protection requirements, but they are not interchangeable labels. The required approval depends on the project, jurisdiction, specification and installation location.
ATEX vs IECEx: What Is the Difference?
ATEX and IECEx both address equipment used in explosive atmospheres, but they operate under different certification frameworks.
Parameter | ATEX | IECEx |
|---|---|---|
Framework | European regulatory framework | International certification system |
Primary scope | Equipment for explosive atmospheres within applicable EU requirements | Equipment assessed against applicable IEC explosion-protection standards |
Documentation | ATEX conformity documentation | IECEx certification documentation |
Application | Required where applicable under European regulations | Used in participating countries and projects accepting IECEx |
Equipment selection | Based on classification and ATEX requirements | Based on classification and IECEx requirements |
For industrial projects, always confirm the specific certification requested by the consultant, EPC contractor, end user or regulatory authority.
Understanding Gas Groups: IIA, IIB and IIC
Gas groups classify explosive gases according to their ignition characteristics and properties relevant to equipment protection.
In commonly used gas classifications:
IIA: Lower ignition severity relative to IIB and IIC gases
IIB: More demanding gas group than IIA
IIC: More stringent gas group covering gases such as hydrogen and acetylene
Equipment certified for a more demanding gas group may be suitable for certain less demanding gas groups, depending on the specific certification and applicable requirements.
However, this should never be assumed without checking the equipment marking and certificate.
What Is Temperature Class in Hazardous Areas?
Temperature class identifies the maximum permitted surface temperature of equipment under specified conditions.
This is important because an equipment surface must not become hot enough to ignite the surrounding explosive atmosphere.
Common temperature classes include:
Temperature Class | Maximum Surface Temperature |
|---|---|
T1 | 450°C |
T2 | 300°C |
T3 | 200°C |
T4 | 135°C |
T5 | 100°C |
T6 | 85°C |
The correct temperature class depends on the ignition temperature of the hazardous substance present.
For example, T6 equipment has a maximum specified surface temperature of 85°C, making it suitable for applications requiring a lower surface-temperature limit, subject to the equipment's certification and operating conditions.
Why Are Flameproof Electric Actuators Used?
Electric actuators are used to automate valves, dampers and other flow-control equipment across industrial facilities.
In hazardous environments, appropriately certified flameproof electric actuators provide automated operation while meeting the explosion-protection requirements of the installation.
They are commonly used in applications involving:
Oil and gas pipelines
Refineries
Petrochemical facilities
Chemical processing plants
Gas handling systems
Fuel storage terminals
Pharmaceutical process facilities
Power generation
Marine installations
A properly selected flameproof electric actuator can support automated valve operation, remote control, process isolation and flow regulation in hazardous industrial environments.
Applications of Flameproof Electric Actuators
Oil and Gas
Flameproof actuators are used for valve automation in gas pipelines, processing units, storage terminals and oil production facilities where hazardous gas atmospheres may be present.
Chemical and Petrochemical Industries
Chemical plants handle a wide range of volatile and flammable materials. Electric actuators may be used to control valves in process lines, transfer systems and chemical handling operations.
Power Plants
Power generation facilities may have hazardous areas associated with fuel handling, gas systems and auxiliary processes.
Marine and Offshore Installations
Marine environments can combine hazardous gases, humidity, salt exposure and demanding operating conditions. Equipment must be selected for both hazardous-area requirements and environmental protection.
Pharmaceutical and Process Industries
Certain manufacturing and processing environments may require appropriately classified electrical equipment based on the materials and operating conditions involved.
How to Select a Flameproof Electric Actuator
Selecting a flameproof electric actuator requires more than checking whether the product is marked Ex d.
The actuator must be compatible with the valve, process conditions, hazardous-area classification and automation requirements.
1. Confirm the Hazardous Area Zone
Determine whether the installation is classified as Zone 1 or Zone 2, or another applicable classification.
The equipment certification must be suitable for the installation zone.
2. Check the Gas Group
Verify the gas group requirement for the area.
The actuator must be certified for the gas group applicable to the installation.
3. Verify the Temperature Class
Confirm that the equipment's maximum surface temperature is appropriate for the hazardous substance present.
4. Select the Correct Actuator Torque
The actuator must provide sufficient torque to operate the valve under actual operating conditions.
Valve torque requirements can vary based on pressure, differential pressure, fluid characteristics, valve type, seat condition and operating frequency.
Incorrect actuator sizing can result in unreliable operation or damage to the valve and actuator.
5. Identify the Valve Type
Actuator selection depends on the type of valve being automated.
Examples include:
Ball valves
Butterfly valves
Plug valves
Globe valves
Dampers
The actuator's output motion and mounting arrangement must match the valve requirements.
6. Check Control Requirements
Determine whether the actuator is required for:
On-Off operation
Inching operation
Modulating control
Remote operation
Local operation
Position feedback
The required control functionality must be available in the selected actuator configuration.
7. Verify Environmental Protection
Hazardous-area protection and environmental protection are different requirements.
Consider:
Dust ingress
Water ingress
Ambient temperature
Corrosion
Outdoor exposure
Humidity
Marine conditions
The required enclosure protection must suit the actual installation.
Flameproof vs Weatherproof Electric Actuators
A weatherproof electric actuator is designed to protect against environmental conditions such as rain, dust and moisture within its specified protection rating.
A flameproof electric actuator is designed and certified for applicable hazardous-area conditions.
These protection types address different risks.
A weatherproof actuator is not automatically suitable for an explosive atmosphere. Similarly, a flameproof actuator must still have the required environmental protection for its operating location.
The selection should always be based on the complete installation specification.
SDTORK Flameproof Electric Actuator Solutions
SDTORK offers flameproof electric actuator solutions designed for valve and damper automation in industrial hazardous-area applications.
The range includes flameproof quarter-turn and linear actuator configurations intended for applications where hazardous-area certification and reliable operation are important.
Depending on the selected model, the actuator range can support different torque or thrust requirements, valve configurations and control modes.
For applications involving Zone 1 and Zone 2 environments, the correct actuator should be selected according to the area classification, certification, gas group, temperature class, process requirements and project specification.
Explore the SDTORK flameproof actuator range to identify a suitable solution for your industrial automation requirements.
Frequently Asked Questions
Is a Zone 1 actuator suitable for Zone 2?
It may be suitable if its certification and equipment protection requirements cover the Zone 2 installation. Always verify the exact equipment marking and certificate.
What is the difference between Ex d and explosion-proof?
Ex d is a specific flameproof enclosure protection concept. Explosion-proof is often used as a general term, but equipment selection must be based on the actual protection method and certification marking.
Does ATEX mean the actuator can be used in every hazardous area?
No. ATEX compliance alone does not mean that an actuator is suitable for every hazardous location. Zone, gas group, temperature class, equipment category and operating conditions must be checked.
Can a flameproof electric actuator be used outdoors?
Yes, provided its environmental protection rating, ambient temperature range, corrosion resistance and installation conditions are appropriate.
Why is gas group important when selecting an actuator?
Gas groups classify gases according to their relevant explosion characteristics. The actuator must have protection and certification appropriate for the gases present in the installation.
Is Ex d the same as IECEx?
No. Ex d describes a flameproof protection concept, while IECEx is an international certification system. Equipment can be certified under a system such as IECEx with an Ex d protection marking, depending on its approvals.
Conclusion
Hazardous area classification is an important part of industrial electrical and automation equipment selection. Understanding Zone 1, Zone 2, Ex d protection, gas groups, temperature classes, ATEX and IECEx helps engineers identify equipment that is appropriate for potentially explosive environments.
When selecting a flameproof electric actuator, the hazardous-area classification should be considered alongside torque requirements, valve type, control mode, environmental conditions and project certification requirements.
Choosing the correct actuator supports reliable operation, equipment compatibility and safer industrial automation.
For hazardous-area valve automation, selecting an actuator with the correct protection and certification is an essential part of engineering the system correctly.
Related Posts
- Nov 14, 2026
- SDTORK
- 10
Electric Actuator Communication Protocols: Modbus, Profibus and HART Explained
Explore More- Oct 31, 2026
- SDTORK
- 10
Modulating vs On-Off Electric Actuators: Working, Applications and Differences
Explore More- Oct 29, 2026
- SDTORK
- 10